Flag icon Flag icon
Associate Professor

Aganovic, Amar

Department of Automation and Process Engineering




Publications in CRIStin


  • Aganovic, Amar; Cao, Guangyu. Evaluation of airborne contaminant exposure in a single-bed isolation ward equipped with a protected occupied zone ventilation system. Indoor and Built Environment 2019; Volum 28 (8). ISSN 1420-326X.s 1092 - 1103.s doi: 10.1177/1420326X18823048.

  • Aganovic, Amar; Cao, Guangyu; Stenstad, Liv-Inger; Skogås, Jan Gunnar. An experimental study on the effects of positioning medical equipment on contaminant exposure of a patient in an operating room with unidirectional downflow. Building and Environment 2019; Volum 165. ISSN 0360-1323.s 1 - 9.s doi: 10.1016/j.buildenv.2019.04.032.

  • Aganovic, Amar; Steffensen, Marie; Cao, Guangyu. CFD study of the air distribution and occupant draught sensation in a patient ward equipped with protected zone ventilation. Building and Environment 2019; Volum 162. ISSN 0360-1323.s doi: 10.1016/j.buildenv.2019.106279.

  • Cao, Guangyu; Storås, Madeleine C. A.; Aganovic, Amar; Stenstad, Liv-Inger; Skogås, Jan Gunnar. Do surgeons and surgical facilities disturb the clean air distribution close to a surgical patient in an orthopedic operating room with laminar airflow?. American Journal of Infection Control 2018; Volum 46 (10). ISSN 0196-6553.s 1115 - 1122.s doi: 10.1016/j.ajic.2018.03.019.

  • Aganovic, Amar; Cao, Guangyu; Stenstad, Liv-Inger; Skogås, Jan Gunnar. Impact of surgical lights on the velocity distribution and airborne contamination level in an operating room with laminar airflow system. Building and Environment 2017; Volum 126. ISSN 0360-1323.s 42 - 53.s doi: 10.1016/j.buildenv.2017.09.024.

  • Cao, Guangyu; Storås, Madeleine C. A.; Aganovic, Amar; Stenstad, Liv-Inger; Skogås, Jan Gunnar. Experimental measurements of thermal plumes from a patient in an operating room with laminar airflow at St. Olavs Hospital. Finnish indoor climate conference 2018-03-15 - 2018-03-15 2018.

  • Aganovic, Amar; Hamon, Mathieu; Kolarik, Jakub; Cao, Guangyu. Indoor air quality in mechanically ventilated residential dwellings/low-rise buildings: A review/analysis of existing information. The 38th AIVC conference "Ventilating healthy low-energy buildings" 2017-09-13 - 2017-09-14 2017.

  • Steffensen, Marie; Aganovic, Amar; Cao, Guangyu. Experimental study of the airflow distribution close to the human body with a downward plane jet. Healthy Buildings 2017 Europe 2017-07-02 - 2017-07-05 2017.

  • Cao, Guangyu; Aganovic, Amar; Stenstad, Liv-Inger; Skogås, Jan Gunnar; Mathisen, Hans Martin. Experimental study of the effect of operation lamps on downward airflow distribution in an operating theatre in St. Olavs Hospital in Norway. Healthy Buildings 2017 Europe 2017-07-02 - 2017-07-05 2017.